The intercom system is activated over a microphone switch on the inside microphone. In this operating condition external noise is audible or it is
possible to speak to the vehicle occupants. The acoustic signals outside the vehicle are picked up by the outside mirror microphones and routed
discretely to the PAS [GAS] and special signal system control unit.

Panic alarm system (GAS) in combination with special signal system

As long as the panic alarm system (GAS) is coupled with a special signal system, the panic alarm system (GAS) always has functional priority, i.e. if the
alarms are switched on at the same time the special signal sequences and the special signal for the exterior lights are suppressed and super imposed by
the previously described alarm functions. Only after pressing the microphone talk button on the inside microphone is the panic alarm system (GAS)
alarm cleared and the special signal system re-activated.

The communication distance to the vehicle is between 3 m and 5 m depending on ambient noise. The PAS [GAS] and special signal system control unit
amplifies the acoustic signals and the interior speaker is actuated over a discrete output. A speaker integrated into the inside microphone is also actuated
so that in the event of any poor sound quality the inside microphone can be placed up against the ear to listen to.

If a panic alarm system (GAS) alarm is triggered the "YELP" alarm signal is interrupted. The microphone switch on the inside microphone must always
be switched off after use, as otherwise the "YELP" acoustic signal in the panic alarm system (GAS) alarm is not actuated.

Voice communications from inside to outside

Pressing the microphone talk button on the inside microphone switches off the outside mirror microphones and the talk option is switched from inside to
outside. The acoustic signals are pre- amplified in the inside microphone with 20 dB and sent discretely to the PAS [GAS] and special signal system
control unit.

The PAS [GAS] and special signal system control unit amplifies this signal and feeds it via a discrete output to the outside speaker. The volume can be
set using the control on the inside microphone.

Pressing the microphone talk button on the inside microphone terminates an actuated panic alarm system (GAS) alarm.