SL 500 (230.475) V8-5.0L (113.963) (2004)
Component Identification
The cable lug to the fuse box (40) should be crimped to the two supply lines (red).
1
Route the branch-off line of the supply lines (red) of the wiring harness for the illuminated door sill molding (1) to the rear signal and acquisition
module (SAM).
2
Route both branch-off lines of the illuminated door sill molding wiring harness (1) to the door contact switches.
The longer branch-off line is routed to the left door contact switch.
3
Guide branch-off line with brown and black/red wire (br, sw/rt) from the illuminated door sill molding wiring harness (1) to the right door contact
switch (S17/4) and secure to existing wires.
4
Tie up standard wiring harness of right door contact switch (S17/4) approx. 60 mm and expose the brown and gray/black wire (br, gr/sw).
5
Using a cable clamping connector, connect the brown cable (br) from the wiring harness for the illuminated door sill molding to the brown cable
(br) of the production wiring harness. Using a cable clamping connector, connect the black/red cable (sw/rt) to the grey/black connector (gr/sw)
6
Connect converter (7) enclosed with 8-pin connector (10) to illuminated door sill molding wiring harness (1). (see right Figure)