SL 500 (230.475) V8-5.0L (113.963) (2004)
^
Ensure wiring harness (A, Figure 24) touches the bracket (C, Figure 24) and is mounted there tension free.
CAUTION!
Ensure harness is properly mounted to allow cable strain relief in area between cable tie and connector.
2.
Quality measure 2:
^
Ensure wiring harness (A, Figure 24) and water hose (B, Figure 24) are not touching each other.
CAUTION!
Risk of chafing if wiring harness and water hose are touching.
3.
Quality measure 3:
^
Ensure tightening torque on ground terminal stud (arrow, Figure 24) is between 7 and 10 Nm.
CAUTION
Risk of breaking ground terminal stud if torque of 10 Nm is exceeded.