SL 500 (230.475) V8-5.0L (113.963) (2004)
(B).
Note:
^
Ensure that the SBC wiring harness (A) is properly routed so that it is free of tension in the SBC connector housing.
^
The cable tie "buckle" (D) must be located at the side of the connector cover harness receptacle (arrow) as depicted.
14.
Secure ground wiring harness (C, Figure 13) to the SBC connector housing receptacle (F) using a new cable tie (E).
15.
Attach bracket (A, Figure 16) to the SBC hydraulic unit (B, Figure 16):