AH00.19-P-1000-09A Notes on Crimping
AH00.19-P-1000-09A Notes On Crimping
1
Check crimped connections for correct forming and filling (cross-section, ensure that leads are enclosed correctly).
Correct crimped connection (A):
The strands of the cable are evenly enclosed.
The crimp tab is evenly shaped.
Incorrect crimped connection (B):
The crimp tab has an incorrect cross-section and is not full enough.
Incorrect crimped connection (C):
Individual wire strands are outside the crimp shackle.
The crimp tab is too full.
Incorrect crimped connection (D):
The crimp claws touch the bottom of the crimped fitting.
The crimp tab is too full.
The crimp tab is deformed and therefore damaged.