mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Electrical Specifications|Page 13496 > < Electrical Specifications|Page 13494
Page 1
background image

Voltage Regulator: Testing and Inspection

Check The Regulator Voltage At The Generator

Connection Diagram

Inspecting

DANGER:

-

Risk of explosion from explosive gas. Risk of poisoning and caustic burns from swallowing battery electrolyte. Risk of caustic burns to
eyes and skin from battery electrolyte or from handling damaged lead-acid batteries

-

No fire, sparks, naked flames or smoking,

-

Wear add-resistant gloves, clothing and eye protection. Pour battery electrolyte only into suitable and appropriately marked containers.

1

Check the condition of the battery

2

Preconditions for generator testing

3

Connect the multimeter (003) as shown in the diagram

4

Set the headlamps on dipped beam for 1 minute

5

Switch off the headlamps

6

Check the quiescent voltage of the on-board electrical system battery (G1)
-

Nominal values >= 12.6 Volt

-

Nominal value < 12.5 Volt

Electrical Specifications|Page 13496 > < Electrical Specifications|Page 13494