01 Relays and Modules02 Sensors and Switches03 Maintenance04 Engine, Cooling and Exhaust05 Powertrain Management06 Transmission and Drivetrain07 Brakes and Traction Control08 Starting and Charging09 Power and Ground Distribution10 Steering and Suspension11 Heating and Air Conditioning12 Restraint Systems13 Accessories and Optional Equipment14 Body and Frame15 Cruise Control16 Instrument Panel, Gauges and Warning Indicators17 Lighting and Horns18 Windows and Glass19 Wiper and Washer Systems
Mercedes Benz SL 55 AMG (230.472) V8-5.5L SC (113.995) (2007)01 · Relays and Modules
01 · Diagnostics

A/C - Blower Motor Inoperative/DTC 09460 Set (Blower Motor Relay)

Make
Mercedes Benz
Model
SL Class SL 55 AMG (230.472)
Engine
V8-5.5L SC (113.995)
Year
2007
Section
Sep › 07 › A/C - Blower Motor Inoperative/DTC 09460 Set
Relays and ModulesA/C - Blower Motor Inoperative/DTC 09460 Set · page 1 of 2
A/C - Blower Motor Inoperative/DTC 09460 Set (Blower Motor Relay) – Mercedes-Benz SL 55 AMG R230 V8-5.5L SC M113 (2007)

Blower Motor Relay: All Technical Service Bulletins
A/C - Blower Motor Inoperative/DTC 09460 Set

Date: September 28, 2007

Order No.: P-B-83.25/76c

Supersedes: P-B-83.25/76b dated March 9, 2007

Group: 83

Revision History

Revision

Date

Purpose

C

9/28/07

Work Instructions, Part Number 
and Warranty Information Updated

b

3/9/07

Applicable Models and Content Updated

a

9/20/06

Addition of Note Pertaining to DTC Code 9460

-

1/10/06

Initial issue

SUBJECT: All 171, 203, 209, 211, 219 and 230 Models 

Heater Blower Motor Stops Running

If you receive customer reports in the above model vehicles that the heater blower motor stops running, the blower motor regulator should be replaced.
The related symptoms for this condition are as follows:

1.

During high blower demand, such as defrost or maximum cooling, the blower starts up and shuts off for approximately 90 seconds. The blower
tries to restart and may shut off again. This cycle may repeat.

2.

Manual adjustment of the blower speed and the blower shuts off for 60 seconds and then restarts.

3.

Once the blower has shut off by itself, cycling the ignition off and back on may allow the blower to operate again.

4.

Diagnostic fault code DTC 9460 may be present.

These conditions may be caused by a high blower output requested by the climate system and the blower regulator overload protection engaging
unnecessarily. Follow the procedures below for corrective actions.

1.

Replace the blower regulator as per the WIS document shown.

Pinch or Ctrl + scroll to zoom. Double-tap to reset.