Heater Control Valve: Description and Operation
GF83.20-P-2112-01R Heat Exchanger Shut-Off Motor, Function

GF83.20-P-2112-01R Heat Exchanger Shut-off Motor, Function

- with CODE (581) Automatic air conditioning

Function

The heat exchanger shut-off motor (M16/32) regulates the flow of temperature-controlled coolant to the heat exchanger.
The heat exchanger shut-off motor (M16/32) is controlled by the AAC pushbutton control module (N22) so that there is always a sufficient quantity of
temperature-controlled coolant available.

Opening of heat exchanger shut-off motor (M16/32)

^

Regulated when the calculated air outlet temperature on one of the two sides is greater than 5 °C.

^

When starting the defroster function by pressing the defroster button.

^

When starting the REST function by pressing the REST button.

Closing of heat exchanger shut-off motor (M16/32)

^

Regulated when the calculated air outlet temperature on one of the two sides is less than 5 °C.

^

When ON/OFF button pressed

^

when engine is switched off

The air outlet temperature is calculated using the following factors:

^

Outside air temperature

^

Inside-air temperature

^

Set temperature selector

^

Fresh/recirculated air