mercedesbenz Workshop Repair Guides

Mercedes Benz Workshop Service and Repair Manuals

Tools and Equipment > < AR09.50-P-8843T Remove/Install Recirculated Air Flap Actuator|Page 9367
Page 1
background image

Air Bypass Valve Actuator: Service and Repair
AR09.50-P-8843-01T Attach Air Recirculation Flap Actuator

AR09.50-P-8843-01T Attach Air Recirculation Flap Actuator

Supercharger

1

Clean sealing surfaces.

2

Insert new seal.

3

Attach air recirculation flap actuator (M16/7) loosely on the charge air cooler. Do not tighten Torx bolts (1).
The air recirculation flap actuator (M16/7) must be movable in order to allow trouble free connection of the charge air cooler and compressor.

4

Connect charge air cooler and compressor together and fix together with bolts.
Do not use sealant since the charge air cooler and compressor will be separated again.

5

Tighten front torx bolt (2) on air recirculation flap actuator (M16/7).

6

Remove bolts and carefully disconnect charge air cooler and compressor.

7

Tighten all Torx bolts on air recirculation flap actuator (M16/7) [Nm].

Tools and Equipment > < AR09.50-P-8843T Remove/Install Recirculated Air Flap Actuator|Page 9367