4

If oil evacuation unit is not available, drain engine oil from oil pan (arrow); for this purpose remove engine compartment panelling at bottom.

Installation Note
Replace sealing ring on oil drain plug (arrow). Tighten drain plug (arrow) to 40 Nm.

5

Replace sealing ring (3).

6

Insert oil filter cartridge (4) into oil filter housing (5).

7

Install screw cap (2) and tighten to 20 Nm.

8

Install left air cleaner housing

9

Open cover (arrow), add engine oil. Allow engine to run and check for leakage.

10

Check oil level approximately 2 minutes after shutting off engine after warming up to operating temperature (arrow).

SPECIAL TOOLS