Turbocharger Coolant Pump: Procedures

AR20.00-P-1145-01R  Actuate circulation pump 

1 Open the rear fuse and relay module (K40/5).
2 Pull out the charge air cooler circulation  pump relay (K60) from the rear fuse and relay module (K40/5). 
3 Plug in the switch (included with the  delivery of the cooler vacuum filling device in the plug position of the charge air cooler circulation pump relay
(K60).
Activate the switch to actuate the  circulation pump . A lamp will light  up on the switch when the circulation  pump is actuated .