Brake Master Cylinder: Testing and Inspection
Abnormal Conditions

Abnormal Conditions 

NOTE:  Prior to carrying out any diagnosis, make sure the brake system warning indicator is functional.

 

Changes in brake pedal feel or travel are indicators that something could be wrong in the brake system. The diagnostic procedure and techniques use
brake pedal feel, warning indicator illumination and low brake fluid level as indicators in diagnosing brake system concerns. The following conditions
are considered abnormal and indicate that the brake master cylinder is in need of repair. 
^

Brake pedal goes down fast. This could be caused by an external or internal leak. 

^

Brake pedal goes down slowly. This could be caused by an external or internal leak. 

^

Brake pedal is low or feels spongy. This condition may be caused by no fluid in the brake master cylinder reservoir, reservoir cap vent holes
clogged or air in the hydraulic system. 

^

Brake pedal effort is excessive. This may be caused by a bind or obstruction in pedal/linkage, clogged fluid control valve or insufficient booster
vacuum.

^

Rear brakes lock up during light pedal force. This may be caused by grease or fluid on brake pads or shoes, damaged brake pads or shoes,
incorrectly adjusted parking brake.

^

Brake pedal effort is erratic. This condition could be caused by the brake booster, extreme caliper piston knock back or incorrectly installed brake
pads or shoes.

^

Brake warning indicator is ON. This may be caused by low fluid level, ignition wire routing too close to fluid level indicator assembly, or float
assembly damage.

 

General Procedures|Page 5675 > < General Procedures