When it is necessary to measure the quantity of refrigerant oil in the suction accumulator/drier, drill two 13 mm (1/2 inch) holes in the body of the
suction accumulator/drier and drain oil through the holes.

In addition to the preceding condition, the suction accumulator/drier should also be replaced if one of the following conditions exists:

^

The suction accumulator/drier is perforated.

^

The refrigerant system has been opened to the atmosphere for a period of time longer than required to make a minor repair.

^

There is evidence of moisture in the system such as internal corrosion of metal refrigerant lines or the refrigerant oil is thick and dark.