mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Customer Interest: > < Engine - Loss of Power/Stalling after Hot Soak
Page 2
background image

1. Disconnect the negative battery cable.

Figure 13

2. Cut the (Yellow - Circuit #37) and the (Light Green with Yellow Stripe - Circuit #354) about 2" from the cooling fan relay connector. Strip and

crimp both leads from the relay connector in one end of a #12 butt connector (C9AB-14488-D) (Figure 13).

3. Strip and crimp the harness end of (Circuit #37 -Yellow) into the other end of the butt connector.

4. Using friction tape (ESB-M3G71-A), tape the end of circuit #354 (Light Green with Yellow Stripe) wire feed back to the harness. Make sure that the

cut end is adequately insulated.

5. Connect the battery and perform a system check by connecting a jumper wire between the #197 circuit Tan-Org Dot and electrical ground. The

engine cooling fan should operate.

6. Install 1982 level Fan Warning Decal (E1EE-8653-AA) over the existing decal.

Warranty Status:

Reimbursable within the provisions of the Warranty and Policy Manual.

Operation:

SP 951O-A-82

Time: 0.3 Hr.
DLR. Coding: Basic Part No. DRIVE Code: 53

Customer Interest: > < Engine - Loss of Power/Stalling after Hot Soak