Page 4
background image

FIGURE 2

Modify the Thermactor Air Control System as Follows:

4.

Refer to Figure 2. Disconnect the black nylon vacuum line from the rear-facing opening of the three-way rubber tee connected to the air cleaner
cold weather modulator. Plug the opening in the three-way rubber tee using a 383001-S stepped straight vacuum connector and a 382444-S
vacuum cap (5/32" i.d.).

FIGURE 3

5.

Refer to Figure 3. Connect a 24-inch length of D0PZ-12226-B vacuum hose (5/32" i.d.) to the open end of the black nylon vacuum line (from step
# 4), using a 90~ vacuum connector (Part Number 387065-S) and a 90~ 5/32" i.d. elbow to barbed nylon connector (Part Number
E3TZ-9E499-C).