Brake Bleeding: Service and Repair
Bleeding System-Hybrid

Brake System Bleeding - Hybrid 

Special Tool(s)

Material

WARNING:  Use of any other than the approved DOT 3 brake fluid will cause permanent damage to brake components and will render the
brakes inoperative. Failure to follow these instructions may result in personal injury.
 

WARNING:  Brake fluid contains polyglycol ethers and polyglycols. Avoid contact with eyes. Wash hands thoroughly after handling. If
brake fluid contacts eyes, flush eyes with running water for 15 minutes. Get medical attention if irritation persists. If taken internally, drink
water and induce vomiting. Get medical attention immediately. Failure to follow these instructions may result in personal injury.
 

CAUTION:  Do not allow the brake master cylinder reservoir to run dry during the bleeding operation. Keep the master cylinder reservoir filled with
the specified brake fluid. Never reuse the brake fluid that has been drained from the hydraulic system.

CAUTION:  Brake fluid is harmful to painted and plastic surfaces. If brake fluid is spilled onto a painted or plastic surface, immediately wash it with
water.

CAUTION:  Do not allow the master cylinder brake fluid to overflow from the reservoir. Brake fluid may damage the high-voltage components.

NOTE:  Bleeding the hydraulic control unit (HCU) is required only when removing or installing the HCU, master cylinder, or opening the lines to the
HCU.

NOTE:  The ignition key must be in the ON position when checking the brake fluid level.

NOTE:  Make sure that the brake fluid level is above the MIN mark.