mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Evaporator Core > < HVAC Module-DATC|Page 6450
Page 1
background image

Coupler HVAC: Description and Operation

Air Conditioning

Refrigerant Line Fittings

NOTICE: Use only a plastic or nonmetallic tool for removing O-ring seals and gasket seals from the refrigerant line fittings. Use of a metallic
tool will create scratches on the sealing surface of the fitting that can result in refrigerant system leaks.

Whenever a refrigerant line fitting is disconnected, the fitting must be cleaned of any foreign material and new O-ring seals and/or gasket seals must be
installed. Use only the O-ring seals and gasket seals specified in the Ford Master Parts Catalog.

If a refrigerant system line fitting must remain disconnected for an extended period of time, it should be capped to avoid contamination of the refrigerant
system.

Evaporator Core > < HVAC Module-DATC|Page 6450