Stoplamps

Pinpoint Tests

Pinpoint Test J: One Or More Stoplamps Are Inoperative

Refer to Wiring Diagram Set 90 (Escape/Mariner, Escape Hybrid/Mariner Hybrid), Turn Signal/Stop/Hazard Lamps for schematic and connector
information.  See: Diagrams/Electrical Diagrams/Diagrams By Number

Normal Operation

When the brake pedal is applied, the stoplamp switch routes voltage to the Smart Junction Box (SJB) and the high mounted stoplamp through circuit
CCB08 (VT/WH). When the SJB detects the brake pedal is applied, the SJB provides voltage to the LH and RH rear stoplamps through circuits CLS18
(GY/BN) and CLS19 (VT/OG), respectively. Ground for the LH and RH rear stoplamps is provided through circuit GD149 (BK/GY). Ground for the
high mounted stoplamp is provided through circuit GD183 (BK/WH).

NOTE: SJB fuse 6 (20A) supplies voltage for both combination rear stop/turn lamps and both front turn lamps.

B106E-B2047

This pinpoint test is intended to diagnose the following:

-

Wiring, terminals or connectors

-

High mounted stoplamp

-

Bulb holder

-

SJB

PINPOINT TEST J: ONE OR MORE STOPLAMPS ARE INOPERATIVE

NOTICE: Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the
connector.

-------------------------------------------------
J1 DETERMINE THE INOPERATIVE STOPLAMP

-

Ignition OFF.

-

Apply the brake pedal and observe the stoplamps.

-

Are all the stoplamps inoperative?

Yes

Initial Inspection and Diagnostic Overview|Page 8829 > < Initial Inspection and Diagnostic Overview|Page 8827