Disconnect all the HVAC module connectors.

-

Check for:
-

corrosion

-

damaged pins

-

pushed-out pins

-

Connect all the HVAC module connectors and make sure they seat correctly.

-

Operate the system and verify the concern is still present.

-

Is the concern still present?

Yes

INSTALL a new HVAC module. CLEAR the DTCs. REPEAT the network test with the scan tool.

No

The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CLEAR the DTCs. REPEAT the
network test with the scan tool.

-------------------------------------------------

Pinpoint Test M: The Satellite Digital Audio Receiver System (SDARS) Module Does Not Respond To
The Scan Tool

Communications Network

Pinpoint Tests

Pinpoint Test M: The Satellite Digital Audio Receiver System (SDARS) Module Does Not Respond To The Scan Tool

Refer to Wiring Diagram Set 14 (Escape/Mariner, Escape Hybrid/Mariner Hybrid), Module Communications Network for schematic and connector
information.  See: Diagrams/Electrical Diagrams/Diagrams By Number

Refer to Wiring Diagram Set 130 (Escape/Mariner, Escape Hybrid/Mariner Hybrid), Audio System for schematic and connector information.  See:
Diagrams/Electrical Diagrams/Diagrams By Number

Normal Operation

The Satellite Digital Audio Receiver System (SDARS) module communicates with the scan tool through the Medium Speed Controller Area Network
(MS-CAN). Circuits VDB06 (GY/OG) (MS-CAN +) and VDB07 (VT/OG) (MS-CAN -) provide the network connection to the SDARS module.
Voltage to the SDARS module is provided by circuit SBP14 (BN/RD). Ground is provided by circuit GD115 (BK/GY).

This pinpoint test is intended to diagnose the following:

-

Fuse

-

Wiring, terminals or connectors

-

SDARS module

PINPOINT TEST M: THE SDARS MODULE DOES NOT RESPOND TO THE SCAN TOOL

NOTICE: Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the
connector.

NOTE: Failure to disconnect the battery when instructed will result in false resistance readings. Refer to Battery.

-------------------------------------------------
M1 CHECK THE SDARS MODULE VOLTAGE SUPPLY CIRCUIT FOR AN OPEN

-

Ignition OFF.

-

Disconnect: SDARS Module C3290.

-

Ignition ON.

-

Measure the voltage between the SDARS module C3290-9, circuit SBP14 (BN/RD), harness side and ground.