S36 CHECK FOR CORRECT APIM OPERATION

-

Disconnect the APIM connector.

-

Check for:
-

corrosion

-

damaged pins

-

pushed-out pins

-

Connect the APIM connector and make sure it seats correctly.

-

Verify the concern is still present.

-

Is the concern still present?

Yes

INSTALL a new APIM. CONNECT all modules. CLEAR the DTCs. REPEAT the network test with the scan tool.

No

The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. REPOWER the SRS. CONNECT all
modules. CLEAR the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
S37 CHECK FOR CORRECT IC OPERATION

-

Disconnect the IC connector.

-

Check for:
-

corrosion

-

damaged pins

-

pushed-out pins

-

Connect the IC connector and make sure it seats correctly.

-

Operate the system and verify the concern is still present.

-

Is the concern still present?

Yes

INSTALL a new IC. CONNECT all modules. CLEAR the DTCs. REPEAT the network test with the scan tool.

No

The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CONNECT all modules. CLEAR
the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
S38 CHECK FOR CORRECT PSCM OPERATION

-

Disconnect all the PSCM connectors.

-

Check for:
-

corrosion

-

damaged pins

-

pushed-out pins

-

Connect all the PSCM connectors and make sure they seat correctly.

-

Operate the system and verify the concern is still present.

-

Is the concern still present?

Yes

INSTALL a new steering column assembly. CONNECT all modules. CLEAR the DTCs. REPEAT the network test with the scan tool.

No

The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CONNECT all modules. CLEAR
the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
S39 CHECK FOR CORRECT TCM OPERATION

Initial Inspection and Diagnostic Overview|Page 2824 > < Initial Inspection and Diagnostic Overview|Page 2822