mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2839 > < Initial Inspection and Diagnostic Overview|Page 2837
Page 78
background image

-

Are the resistances greater than 1,000 ohms?

Yes

CONNECT the negative battery cable. GO to U30.

No

GO to U23.

-------------------------------------------------
U23 CHECK THE MS-CAN (+) AND MS-CAN (-) CIRCUITS FOR A SHORT TO GROUND WITH THE ACM DISCONNECTED

-

Disconnect: ACM C240b.

-

Measure the resistance between the DLC C251-3, circuit VDB06 (GY/OG), harness side and ground; and between the DLC C251-11, circuit
VDB07 (VT/OG), harness side and ground.

-

Are the resistances greater than 1,000 ohms?

Yes

CONNECT the negative battery cable. GO to U31.

No

If the vehicle is equipped with an APIM, GO to U24.

If the vehicle is not equipped with an APIM, GO to U25.

-------------------------------------------------
U24 CHECK THE MS-CAN (+) AND MS-CAN (-) CIRCUITS FOR A SHORT TO GROUND WITH THE APIM DISCONNECTED

-

Disconnect: APIM C3338.

-

Measure the resistance between the DLC C251-3, circuit VDB06 (GY/OG), harness side and ground; and between the DLC C251-11, circuit
VDB07 (VT/OG), harness side and ground.

-

Are the resistances greater than 1,000 ohms?

Yes

CONNECT the negative battery cable. GO to U32.

No

GO to U25.

-------------------------------------------------
U25 CHECK THE MS-CAN (+) AND MS-CAN (-) CIRCUITS FOR A SHORT TO GROUND WITH THE HVAC MODULE

Initial Inspection and Diagnostic Overview|Page 2839 > < Initial Inspection and Diagnostic Overview|Page 2837