mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Suction Accumulator to Compressor Line|Page 2024 > < Suction Accumulator to Compressor Line|Page 2022
Page 8
background image

Evaporator Inlet Line

EVAPORATOR INLET LINE

Removal and Installation

NOTE:  Installation of a new suction accumulator is not required when repairing the air conditioning system, except when there is physical evidence of
contamination from a failed A/C compressor or damage to the suction accumulator.

1. Recover the refrigerant.
2. Loosen the nut and disconnect the passenger zone valve outlet tube-O fitting.

-

Discard the O-ring seals.

-

To install, tighten to 17 Nm (13 lb-ft).

3. Loosen the nut and disconnect the evaporator inlet line tube-O fitting.

-

Discard the O-ring seals.

-

To install, tighten to 24 Nm (18 lb-ft).

4. Remove the evaporator inlet line.
5. To install, reverse the removal procedure.

-

Install new O-ring seals.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

6. Evacuate, leak test and charge the refrigerant system.

Evaporator Inlet Line - Orifice Tube

EVAPORATOR INLET LINE - ORIFICE TUBE

Suction Accumulator to Compressor Line|Page 2024 > < Suction Accumulator to Compressor Line|Page 2022