mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Communications Network|Page 3389 > < Communications Network|Page 3387
Page 14
background image

G8-G9

Normal Operation

The medium speed CAN has an unshielded twisted pair cable, circuits 1847 (WH/OG) and 1848 (PK/OG). The smart junction box (SJB) and the
instrument cluster are the only modules on the medium speed CAN. Total network resistance values must not be more than 5 ohms. If the resistance is
more than 5 ohms, there is an open in one of the medium speed CAN circuits, damage to the data link connector (DLC) C251, damage to one of the
network module connectors, or damage to an in-line connector. Since both the SJB and the instrument cluster share network termination
responsibilities, a problem in either of these modules can result in a medium speed CAN failure.

Possible Causes

-

medium speed CAN circuit 1847 (WH/OG) open, short to ground, or short to voltage

-

medium speed CAN circuit 1848 (PK/OG) open, short to ground, or short to voltage

-

SJB voltage circuit 1052 (TN/BK) open

-

SJB ground circuit 570 (BK/WH) open

-

DLC C251

-

instrument cluster

-

SJB

-

SJB fuse 7 (10A)

Test H: No High Speed Controller Area Network (CAN) Communication

PINPOINT TEST H: NO HIGH SPEED CONTROLLER AREA NETWORK (CAN) COMMUNICATION

Communications Network|Page 3389 > < Communications Network|Page 3387