M1-M3

Normal Operation

The instrument cluster communicates with the diagnostic tool through the high speed controller area network (CAN), circuits 1908 (WH) and 1909
(BK). If one of the bus wires becomes shorted to ground or voltage, communications can continue at a reduced level. Check circuits 1908 (WH) and
1909 (BK) between the instrument cluster C220 and the data link connector (DLC) C251. Also check circuits 1847 (WH/OG) and 1848 (PK/OG)
between the instrument cluster C220 and the data link connector (DLC) C251. Total resistance values must not be more than 5 ohms. If the resistance
is more than 5 ohms there is an open in one of the high speed CAN circuits, damage to the DLC C251, damage to the instrument cluster C220, or a
problem in an in-line connector.

Possible Causes

Communications Network|Page 3403 > < Communications Network|Page 3401