Page 15
background image

GO to D18.

No

INSTALL a new DC/DC converter. REFER to Direct Current/Direct Current (DC/DC) Converter  . CLEAR the DTCs. REPEAT the self-test.

-------------------------------------------------
D18 CHECK THE DC/DC CONVERTER USING THE PCM DC/DC CONVERTER ENABLE (DCE) PID

-

Ignition OFF.

-

Connect: DC/DC Converter C1457A.

-

Ignition ON.

-

Enter the following diagnostic mode on the scan tool: DataLogger - PCM.

-

Measure the battery voltage.

-

While monitoring the measured battery voltage, command the PCM DCE active command on and off.

-

Does the battery voltage increase and decrease in accordance with the cycling of the active command?

Yes

CLEAR the DTCs. GO to D19.

No

GO to D26.

-------------------------------------------------
D19 CHECK THE DC/DC CONVERTER FAULT CIRCUIT FOR AN OPEN

-

Ignition OFF.

-

Disconnect: DC/DC Converter C1457A (if not previously disconnected).

-

Disconnect: PCM C175B.

-

Measure the resistance between DC/DC converter C1457A-6, circuit CYD04 (BU/OG), harness side, and PCM C175B-8, circuit CYD04
(BU/OG), harness side.

-

Is the resistance less than 5 ohms?

Yes

GO to D20.

No

REPAIR the circuit. CLEAR the DTCs. REPEAT the self-test.

-------------------------------------------------
D20 CHECK THE DC/DC CONVERTER FAULT CIRCUIT FOR A SHORT TO VOLTAGE

Initial Inspection and Diagnostic Overview|Page 5581 > < Initial Inspection and Diagnostic Overview|Page 5579