7. Position the generator B+ protective cover aside and remove the generator B+ terminal nut.

-

To install, tighten to 17 Nm (150 lb-in).

8. Remove the 3 A/C compressor bolts. Use a tie-strap and position the A/C compressor aside.

-

To install, tighten to 25 Nm (18 lb-ft).

9. Loosen the 2 generator nuts.

-

To install, tighten to 47 Nm (35 lb-ft).

10. Remove the 2 lower generator studs.

-

To install, tighten to 7 Nm (62 lb-in).

11. Remove the upper generator bolt and the generator.

-

To install, tighten to 47 Nm (35 lb-ft).

12. To install, reverse the removal procedure.