mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 3118 > < Initial Inspection and Diagnostic Overview|Page 3116
Page 11
background image

-------------------------------------------------
C5 CHECK THE HS-CAN CIRCUITS BETWEEN THE DLC AND THE IPC FOR AN OPEN - HYBRID

 

-

Measure the resistance between the IPC C220-15, circuit VDB04 (WH/BU), harness side and the DLC C251-6, circuit VDB04 (WH/BU), harness
side.

-

Measure the resistance between the IPC C220-14, circuit VDB05 (WH), harness side and the DLC C251-14, circuit VDB05 (WH), harness side.

-

Are the resistances less than 5 ohms?

Yes

GO to C7. 

No

REPAIR the circuit in question. CONNECT the negative battery cable. CLEAR the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
C6 CHECK THE MS-CAN CIRCUITS BETWEEN THE DLC AND THE IPC FOR AN OPEN - GASOLINE

 

-

Measure the resistance between the IPC C220-12, circuit VDB06 (GY/OG), harness side and the DLC C251-3, circuit VDB06 (GY/OG), harness
side.

-

Measure the resistance between the IPC C220-13, circuit VDB07 (VT/OG), harness side and the DLC C251-11, circuit VDB07 (VT/OG), harness
side.

Initial Inspection and Diagnostic Overview|Page 3118 > < Initial Inspection and Diagnostic Overview|Page 3116