mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 3162 > < Initial Inspection and Diagnostic Overview|Page 3160
Page 55
background image

-

Ignition OFF.

-

Disconnect: SOD-R C4229 .

-

Ignition ON.

-

Measure the voltage between the SOD-R C4229-5, circuit CBP35 (YE/GY), harness side and ground.

-

Is the voltage greater than 10 volts?

Yes

GO to S2. 

No

VERIFY the Smart Junction Box (SJB) fuse 35 (10A) is OK. If OK, REPAIR the circuit in question. If not OK, REFER to the Wiring Diagrams to
identify the possible causes of the circuit short  See: Diagrams/Electrical Diagrams/Diagrams By Number. CLEAR the DTCs. REPEAT the network test
with the scan tool.

-------------------------------------------------
S2 CHECK THE SOD-R GROUND CIRCUIT FOR AN OPEN

 

-

Ignition OFF.

-

Disconnect: Negative Battery Cable .

-

Measure the resistance between the SOD-R C4229-2, circuit GD171 (BK/GY), harness side and ground.

-

Is the resistance less than 5 ohms?

Yes

GO to S3. 

No

REPAIR the circuit. CONNECT the negative battery cable. CLEAR the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
S3 CHECK THE MS-CAN CIRCUITS BETWEEN THE SOD-R AND THE DLC FOR AN OPEN

 

-

Measure the resistance between the SOD-R C4229-4, circuit VDB06 (GY/OG), harness side and the Data Link Connector (DLC) C251-3, circuit
VDB06 (GY/OG), harness side.

Initial Inspection and Diagnostic Overview|Page 3162 > < Initial Inspection and Diagnostic Overview|Page 3160