Milan FWD L4-2.5L (2010)
![background image](/mercury/milan_fwd/l4-2.5l/Page-1038145.png)
-
Are the resistances less than 5 ohms?
Yes
CONNECT the negative battery cable. REPAIR the scan tool. REPEAT the network test with the scan tool.
No
CONNECT the negative battery cable. REPAIR the circuit in question. REPEAT the network test with the scan tool.
-------------------------------------------------