Is the voltage greater than 10 volts?

Yes

GO to A4.

No

VERIFY the Battery Junction Box (BJB) fuse 47 (10A) is OK. If OK, REPAIR circuit CBK03 (GY). If not OK, REFER to the Wiring Diagrams to
identify the possible causes of the circuit short  See: Diagrams/Electrical Diagrams/Diagrams By Number.
CLEAR the DTC. REPEAT the self-test. TEST the system for normal operation.

-------------------------------------------------
A4 CLEAR DTCs AND CARRY OUT SELF-TEST OF THE DC/DC

 

-

Using the scan tool, clear the DC/DC DTCs.

-

Wait a minimum of 65 seconds before carrying out the next step.

-

Enter the following diagnostic mode on the scan tool: Self Test - DC/DC.

-

Is DTC P0A12:16 reported?

Yes

INSTALL a new DC/DC. REFER to Direct Current/Direct Current (DC/DC) Converter  . REPEAT the self-test.
TEST the system for normal operation.

No

Concern is not present at this time. INSPECT the PCM relay control input to DC/DC C1457D-7, circuit CBK03 (GY) for intermittent faults. CLEAR the
DTC. REPEAT the self-test. TEST the system for normal operation.

------------------------------------------------

Pinpoint Test B: DTC P0A94:4B

High-Voltage Converter/Inverter

Pinpoint Tests

 

Initial Inspection and Diagnostic Overview|Page 6298 > < Initial Inspection and Diagnostic Overview|Page 6296