Is the voltage greater than 10 volts?

Yes

GO to U2. 

No

VERIFY the SJB fuse 5 (10A) is OK. If OK, REPAIR the circuit. CLEAR the DTCs. REPEAT the network test with the scan tool. If not OK, REFER to
the Wiring Diagrams to identify the possible causes of the circuit short  See: Diagrams/Electrical Diagrams/Diagrams By Number.

-------------------------------------------------
U2 CHECK THE SJB GROUND CIRCUIT FOR AN OPEN

 

-

Ignition OFF.

-

Disconnect: Negative Battery Cable .

-

Disconnect: SJB C2280d .

-

Measure the resistance between the SJB C2280d-8, circuit GD126 (BK/WH), harness side and ground; and between the SJB C2280d-12, circuit
GD126 (BK/WH), harness side and ground.

-

Are the resistances less than 5 ohms?

Yes

GO to U3. 

No

REPAIR the circuit in question. CONNECT the negative battery cable. CLEAR the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
U3 CHECK THE MS-CAN CIRCUITS BETWEEN THE SJB AND THE DLC FOR AN OPEN

 

-

Disconnect: SJB C2280b .

-

Measure the resistance between the SJB C2280b-37, circuit VDB06 (GY/OG), harness side and the DLC C251-3, circuit VDB06 (GY/OG),
harness side.

-

Measure the resistance between the SJB C2280b-38, circuit VDB07 (VT/OG), harness side and the DLC C251-11, circuit VDB07 (VT/OG),
harness side.