mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 3195 > < Initial Inspection and Diagnostic Overview|Page 3193
Page 63
background image

-

Is the resistance less than 5 ohms?

Yes

GO to V3. 

No

REPAIR the circuit. CONNECT the negative battery cable. CLEAR the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
V3 CHECK THE MS-CAN CIRCUITS BETWEEN THE HVAC MODULE AND THE DLC FOR AN OPEN

 

-

Measure the resistance between the HVAC module C2357a-25 (manual), C228a-25 or

C2356a-25 (DATC), circuit VDB06 (GY/OG), harness side and the
Data Link Connector (DLC) C251-3, circuit VDB06 (GY/OG), harness side.

-

Measure the resistance between the HVAC module C2357a-26 (manual), C228a-26 or

C2356a-26 (DATC), circuit VDB07 (VT/OG), harness side and the DLC C251-11, circuit VDB07 (VT/OG), harness side.

-

Are the resistances less than 5 ohms?

Yes

CONNECT the negative battery cable. GO to V4. 

No

REPAIR the circuit as necessary. CONNECT the negative battery cable. CLEAR the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
V4 CHECK FOR CORRECT HVAC MODULE OPERATION

 

-

Disconnect all the HVAC module connectors.

-

Check for:
-

corrosion