Milan FWD V6-3.0L (2010)
side.
-
Is the resistance between 108 and 132 ohms?
Yes
GO to AC6.
No
GO to AC9.
-------------------------------------------------
AC6 CHECK THE MS-CAN TERMINATION RESISTOR WITH THE SJB DISCONNECTED
-
Disconnect: Smart Junction Box (SJB) C2280b .
-
Measure the resistance between the DLC C251-3, circuit VDB06 (GY/OG), harness side and the DLC C251-11, circuit VDB07 (VT/OG), harness
side.
-
Is the resistance between 108 and 132 ohms?
Yes
GO to AC7.
No
GO to AC8.
-------------------------------------------------
AC7 CHECK THE MS-CAN CIRCUITS BETWEEN THE SJB AND THE DLC FOR AN OPEN
-
Measure the resistance between the SJB C2280b-37, circuit VDB06 (GY/OG), harness side and the DLC C251-3, circuit VDB06 (GY/OG),
harness side.
-
Measure the resistance between the SJB C2280b-38, circuit VDB07 (VT/OG), harness side and the DLC C251-11, circuit VDB07 (VT/OG),
harness side.