Page 110
background image

the scan tool. 

No

The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CONNECT all modules. CLEAR
the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
AC59 CHECK FOR CORRECT HVAC MODULE OPERATION

 

-

Disconnect all the HVAC module connectors.

-

Check for:
-

corrosion

-

damaged pins

-

pushed-out pins

-

Connect all the HVAC module connectors and make sure they seat correctly.

-

Operate the system and verify the concern is still present.

-

Is the concern still present?

Yes

INSTALL a new HVAC module. CONNECT all modules. CLEAR the DTCs. REPEAT the network test with the scan tool. 

No

The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CONNECT all modules. CLEAR
the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
AC60 CHECK FOR CORRECT GPSM OPERATION

 

-

Disconnect the GPSM connector.

-

Check for:
-

corrosion

-

damaged pins

-

pushed-out pins

-

Connect the GPSM connector and make sure it seats correctly.

-

Operate the system and verify the concern is still present.

-

Is the concern still present?

Yes

INSTALL a new GPSM. REFER to Accessories and Optional Equipment. CLEAR the DTCs. CONNECT all modules. REPEAT the network test with
the scan tool. 

No

The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CLEAR the DTCs. CONNECT all
modules. REPEAT the network test with the scan tool.

-------------------------------------------------
AC61 CHECK FOR CORRECT IPC OPERATION

 

-

Disconnect the IPC connector.

-

Check for:
-

corrosion

-

damaged pins

-

pushed-out pins

-

Connect the IPC connector and make sure it seats correctly.

-

Operate the system and verify the concern is still present.

Initial Inspection and Diagnostic Overview|Page 3242 > < Initial Inspection and Diagnostic Overview|Page 3240