Third Row Dome Lamp C963

Test A: The Interior Lamps Are Inoperative

PINPOINT TEST A: THE INTERIOR LAMPS ARE INOPERATIVE

A1-A2

Normal Operation

Under normal operation, when the smart junction box (SJB) turns ON the interior lamps, it provides voltage to the individual lamps through circuit 53
(BK/LB) (courtesy) or 705 (LG/OG) (demand). Ground for the lamps is provided through circuit 1205 (BK).

Possible Causes

-

An open in circuit 1205 (BK)

-

Smart junction box (SJB)

Test B: The Interior Lamps Are Inoperative Using The Dimmer Control