mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Communications Network|Page 3940 > < Communications Network|Page 3938
Page 16
background image

C220 and the data link connector (DLC) C251. The total resistance values must not be more than 5 ohms. If the resistance is more than 5 ohms there
is an open in one of the high speed CAN circuits, damage to the DLC C251, damage to the instrument cluster C220, or a problem in an in-line
connector.

Possible Causes

-

high speed CAN circuit 1908 (WH) or 1909 (BK) short to ground or open

-

medium speed CAN circuit 2180 (WH/BK) or 2181 (BK/YE) short to ground or open

-

DLC C251

-

instrument cluster C220

-

instrument cluster

Test F: The Powertrain Control Module (PCM) Does Not Respond To The Diagnostic Tool

PINPOINT TEST F: THE POWERTRAIN CONTROL MODULE (PCM) DOES NOT RESPOND TO THE DIAGNOSTIC TOOL

F1-F2

Communications Network|Page 3940 > < Communications Network|Page 3938