mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Communications Network|Page 3942 > < Communications Network|Page 3940
Page 18
background image

G1-G2

G2-G3

Normal Operation

The RCM communicates with the diagnostic tool through the high speed controller area network (CAN), circuits 1908 (WH) and 1909 (BK). The high
speed CAN remains operational with the severing of one of the high speed CAN circuits or if the data minus circuit is shorted to ground.
Communication may also continue if one of the termination resistors is lost. The high speed CAN does not remain operational if the data plus circuit is
shorted to ground or shorted to voltage. The high speed CAN also does not remain operational if the data minus circuit is shorted to voltage. Check
circuits 1908 (WH) and 1909 (BK) between the RCM C310b and the data link connector (DLC) C251. The total resistance values must not be more
than 5 ohms. If the resistance is more than 5 ohms there is an open in one of the high speed CAN circuits, damage to the DLC C251, damage to the

Communications Network|Page 3942 > < Communications Network|Page 3940