mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 6191 > < Diagram Information and Instructions|Page 6189
Page 1
background image

Pressure Regulating Solenoid: Service and Repair

Electronic Pressure Control (EPC) Solenoid

Removal

1. Remove the manual control lever.

2. CAUTION: Do not pull on the molded lead frame. This may cause damage to the connector ends. Carefully pry up on the locking tabs to

disconnect the solenoids. Disconnect the molded lead frame from the solenoids.

Disconnect the molded lead frame from the solenoids.

Diagram Information and Instructions|Page 6191 > < Diagram Information and Instructions|Page 6189