mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Tune-up and Engine Performance Checks > < Variable Camshaft Timing (VCT) Valve 1|Page 3297
Page 1
background image

Variable Valve Timing Solenoid: Service and Repair

VARIABLE CAMSHAFT TIMING (VCT) OIL CONTROL SOLENOID

Removal and Installation

1. Disconnect the battery ground cable.
2. Disconnect the variable camshaft timing (VCT) oil control solenoid electrical connector.
3. Remove the grommet.
4. Remove the bolt and the VCT oil control solenoid.

-

To install, tighten to 5 Nm (44 lb-in).

5. To install, reverse the removal procedure

Tune-up and Engine Performance Checks > < Variable Camshaft Timing (VCT) Valve 1|Page 3297