mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Vehicle Speed Sensor > < Variable Camshaft Timing (VCT) Valve 1|Page 4699
Page 1
background image

Variable Valve Timing Solenoid: Service and Repair

VARIABLE CAMSHAFT TIMING (VCT) OIL CONTROL SOLENOID

Removal and Installation

1. Disconnect the battery ground cable.
2. Disconnect the variable camshaft timing (VCT) oil control solenoid electrical connector.
3. Remove the grommet.
4. Remove the bolt and the VCT oil control solenoid.

-

To install, tighten to 5 Nm (44 lb-in).

5. To install, reverse the removal procedure

Vehicle Speed Sensor > < Variable Camshaft Timing (VCT) Valve 1|Page 4699