mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Expansion Valve|Service and Repair|Page 7655 > < Expansion Block/Orifice Tube|Description and Operation|Page 7651
Page 1
background image

Expansion Valve: Service and Repair

THERMOSTATIC EXPANSION VALVE

Removal and Installation

NOTE:  An in-line filter is installed in the auxiliary evaporator inlet line at the floorpan bracket connection. A restriction in this filter may cause
misdiagnosis of a failed thermostatic expansion valve (TXV). This filter must be inspected before a new TXV is installed.

1. Recover the refrigerant.
2. Remove the D-pillar trim panel.
3. Detach the rear portion of the LH quarter trim panel and position away from the TXV.
4. Remove the 4 clips and the TXV cover.
5. Remove the insulating tape.

-

Retain the tape for reuse.

6. Remove the temperature sensing bulb clip and detach the temperature sensing bulb from the evaporator outlet line.

Expansion Valve|Service and Repair|Page 7655 > < Expansion Block/Orifice Tube|Description and Operation|Page 7651