The SJB utilizes a FET protective circuit strategy for many of its outputs (for example, the headlamp output circuit). Output loads (current level) are
monitored for excessive current (typically short circuits) and are shut down (turns off the voltage or ground provided by the module) when a fault is
detected. A continuous DTC is stored at the time of the fault. The circuit then resets after a customer demand of the function (switching the component
on, battery saver being energized). When an excessive circuit load occurs several times, the module shuts down the output until a repair procedure is
carried out. At the same time, the continuous DTC that was stored on the first failure cannot be cleared by a command to clear the continuous DTCs.
The module does not allow this code to be cleared or the circuit restored to normal until a successful on-demand self-test proves that the fault has been
repaired. After the on-demand self-test has successfully completed (no on-demand DTCs present), the continuous DTC clears and the circuit function
returns.

Each circuit has 3 predefined levels of short circuit tolerance established in the module based on each circuits' capability. When the first or second
level is reached, the continuous DTC associated with the circuit sets along with DTC B106E. These DTCs may be cleared using the Clear DTC
operation on the scan tool as long as the fault itself has been corrected. If any of the circuits are shorted past the third level, then B106F and B1342 set
along with the associated continuous DTC. These DTCs cannot be cleared and the module must be replaced.