Mystique V6-153 2.5L DOHC VIN L SFI (1999)
Compressor Fitting HVAC: Service and Repair
Spring Lock Coupling Disconnect Tool Set
SPECIAL TOOL(S)
REMOVAL
1. Reclaim the refrigerant.
2. Raise and support the vehicles.
3. Remove the radiator splash shield
4. Remove the line connection from the compressor.
NOTE: Seal the line and the connection with plugs.
5. Remove the upper line from the air conditioning condenser.