mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Sunroof / Moonroof Switch|Service and Repair > < Sunroof / Moonroof Motor|Removal|Page 12448
Page 1
background image

Sunroof / Moonroof Switch: Testing and Inspection

1. With the roof sliding panel switch in the NEUTRAL position, there should be no resistance between any terminals and terminal 8.

NOTE:  Use an Ohmmeter such as Rotunda Digital Volt-Ohmmeter 014-00407 or equivalent to test the roof sliding panel switch.

2. When the raised portion of the roof sliding panel switch is pushed (to close the roof opening glass), there should be resistance between Terminal 4

and Terminal 8. All other terminals should be disconnected from 4 and 8.

3. When the indented portion of the roof sliding panel switch is pushed (to open the roof opening glass), there should be resistance between

Terminals 5 and 8. All other terminals should be disconnected from 5 and 8.

4. If the portion of the roof sliding panel switch marked UP is pressed (to tilt the roof opening glass up), there should be resistance between

Terminals 6 and 8. All other terminals should be disconnected from 6 and 8.

If the portion of the roof sliding panel switch marked DOWN is pressed (to close the tilted up roof opening glass), there should be resistance
between Terminals 7 and 8. All other terminals should be disconnected from 7 and 8.

If the roof sliding panel switch does not test, replace the roof sliding panel switch.

Sunroof / Moonroof Switch|Service and Repair > < Sunroof / Moonroof Motor|Removal|Page 12448