mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Turn Signal Switch|Flow of Diagnosis|Page 13804 > < Turn Signal Switch|Specifications|Page 13801
Page 1
background image

Turn Signal Switch: Flow of Diagnosis

1. Verify the customer's original concern by operating the switches to duplicate the condition:

^

in RUN without the engine running.

^

in START before the ignition switch is released.

^

in RUN with the engine running.

2. Inspect to determine if any of the following mechanical or electrical concerns apply:

Mechanical
^

Damaged switch.

^

Low fluid level (washer system)

Electrical
^

Fuses.

^

Circuit wiring

^

Generic electronic module

3. If inspection reveals an obvious concern that can be readily serviced, correct the concern before continuing with Inspection and Verification.
4. If a concern remains after the inspection, use the Rotunda New Generation STAR (NGS) Tester 007-00500 or equivalent, connected to the data

link connector (DLC) located beneath the instrument panel to execute Self Test Diagnostics for the generic electronic module (GEM).

5. If self test is passed and no diagnostic trouble codes (DTCs) are retrieved, GO to the Symptom Chart to continue diagnosis.
6. If diagnostic trouble codes (DTCs) are retrieved, GO to the GEM Diagnostic Trouble Codes (DTC) Index to continue diagnostics.
7. If the GEM module cannot be accessed by the New Generation Star (NGS) Tester or equivalent, go to Pinpoint Test A.

Turn Signal Switch|Flow of Diagnosis|Page 13804 > < Turn Signal Switch|Specifications|Page 13801