mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Alternator|Service and Repair > < Generator General Description
Page 1
background image

Alternator: Description and Operation
Generator Circuit Description

CIRCUIT DESCRIPTION

Battery Positive Voltage (B+) Output
The B+ circuit, Circuit 36 (Y/W):
^

supplies the generator output current to the power distribution box.

^

is always hot.

I Circuit
The I circuit, Circuit 904 (LG/R):
^

turns the Voltage Regulator (VR) on when the ignition switch is in the RUN position.

^

turns the generator warning indicator on if there is a problem in the charging system or associated wiring.

A Circuit
The A circuit, Circuit 35 (O/LB):
^

is used by the voltage regulator to sense battery voltage.

^

supplies current to the generator field coil.

^

is always hot.

^

is protected by a fuse in the power distribution box.

Alternator|Service and Repair > < Generator General Description