3. Connect A/C manifold and tube to A/C condenser core inlet tube using new O-ring seals lubricated with clean PAG Compressor Oil Motorcraft

YN-12c F7AZ-19589-DA or equivalent meeting Ford specification WSH-M1C231-B.

4. Connect A/C manifold and tube to suction accumulator/drier using new O-ring seals lubricated with clean PAG Compressor Oil Motorcraft

YN-12c F7AZ-19589-DA or equivalent meeting Ford specification WSH-M1C231-B.

5. Install A/C pressure cut-off switch electrical connector.
6. Lubricate new O-ring seals with clean refrigerant oil and position them in O-ring seal grooves of A/C manifold and tube.
7. Apply Pipe Sealant with Teflon (R) D8AZ-19554-A or equivalent meeting Ford specifications WSK-M2G350-A2 to threads of manifold retaining

bolt.

8. Position A/C manifold and tube with O-ring seals to A/C compressor. Install retaining bolt and tighten to 17-23 N.m (13-16 Lb-Ft).
9. Install water inlet tube.

10. Reinstall radiator assembly.
11. Leak-test, evacuate and charge system. Observe all safety precautions.

Condenser HVAC > < Compressor Fitting HVAC|Specifications|Page 7528