mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Spring Lock Couplings|Page 3171 > < Spring Lock Couplings|Page 3169
Page 2
background image

-

Before working on or disconnecting any of the fuel tubes or fuel system components, relieve the fuel system pressure to prevent accidental
spraying of fuel. Fuel in the fuel system remains under high pressure, even when the engine is not running. Failure to follow this instruction may
result in serious personal injury.

1. If servicing a liquid fuel tube quick connect coupling, release the fuel system pressure.

2. NOTE:  When reusing liquid or vapor tube quick connect couplings, make sure to use compressed air to remove any foreign material from the

retaining clip area before disconnecting from the tube. Apply clean engine oil to the end of the tube before connecting the quick connect coupling.

Spread the legs of the retainer clip and pull it to the outward position in the quick connect coupling.

3. Depress the retainer clip and disconnect the quick connect coupling from the tube.

Connect - Type II

1. NOTE:  Apply clean engine oil to the end of the tube and quick connect coupling O-ring seals.

Install the quick connect coupling onto the tube until fully seated.

2. NOTE:  Make sure the retainer clip is fully seated and locked onto the tube by pulling on the quick connect coupling.

Press the retainer clip into the quick connect coupling body until flush and the legs are locked in place.

Spring Lock Couplings|Page 3171 > < Spring Lock Couplings|Page 3169