Air Cleaner Housing: Service and Repair

AIR CLEANER

Exploded View

Removal and Installation

1. Disconnect the mass air flow (MAF) sensor electrical connector.
2. Loosen the clamp and disconnect the air cleaner outlet pipe from the air cleaner.

-

To install, tighten to 5 Nm (44 lb-in).

3. Remove the 2 bolts from the air cleaner assembly.

-

To install, tighten to 5 Nm (44 lb-in).

4. Separate the 2 air cleaner feet from the rubber grommets and remove the air cleaner assembly.

5. NOTE:

-

Make sure that the 2 air cleaner feet are seated into the rubber grommets under the air cleaner assembly and the 2 air cleaner assembly bolts are
tightened to specification.

-

The air cleaner outlet pipe should be securely sealed to prevent unmetered air from entering the engine.

To install, reverse the removal procedure.

Fuel Filter > < Idle Speed|Specifications