mercury Workshop Repair Guides

Mercury Workshop Service and Repair Manuals

Audible Warning Device Control Module|Locations|Page 9262 > < Audible Warning Device Control Module|Locations|Page 9260
Page 1
background image

Audible Warning Device Control Module: Service and Repair

REMOVAL 

1. Disconnect the battery ground cable.

CAUTION:  Electronic modules are sensitive to static electrical charges. If modules are exposed to these charges, damage may result.

2. Remove the two pushpins and the LH cowl side trim panel.

3. Push inward on the clip and pull out on the safety belt warning chime from the back of the interior fuse junction panel.

INSTALLATION 

Audible Warning Device Control Module|Locations|Page 9262 > < Audible Warning Device Control Module|Locations|Page 9260